Thermal Expansion Information

ATTENTION: Agate Water customers who have a Backflow Prevention Assembly (BPA) on the water service line to your home or place of business.

All customers who have a BPA on the water service line to your home or place of business need to be aware of thermal expansion.

Water heaters are installed with a temperature and pressure valve (T&P) which is designed to relieve excessive water temperature or pressure. Also aiding in the control of excessive heat & pressure is a condition known as thermal expansion which allows extremely hot water to backflow through the water meter into the water main line, mixing with the cold water and dissipating the heat.

However, when a BPA is installed on a water service line the water cannot go back out into the water system. This leaves the T&P valve as the only release route for t he overheated water. If the water heater thermostat becomes defective allowing the water temperature to increase to more than 212 degrees and the T&P valve fails, the water can become “superheated”. Superheated water can cause water heaters to explode or can allow scalding steam to be released from the faucets upon personal use.

This condition is rare, because the water heater thermostat and the T&P valve must both malfunction simultaneously. However, with the BPA in place, the potential hazard exists.

Agate Water Company recommends that the T&P valve be inspected periodically. A licensed plumber can inspect, repair or replace the T &P valve and assist you with other methods of protection such as installing a thermal expansion tank for added protection.

References: http://public.health.oregon.gov/HealthyEnvironments/DrinkingWater/Rules/Documents/61-0070.pdf

OAR CHAPTER 333
Division 061
Effective 2-1-06
333-061-0070 Cross Connection Control Requirements

(8) Premise isolation requirements: (A) The water supplier shall (iii) Notify the premise owner and water user, in writing, of thermal expansion concerns.

AGATE WATER OUTDOOR/LANDSCAPE WATERING HOURS   Please avoid watering during peak domestic hours whenever possible, which are 6:00am to 9:00am and 5:00pm and 9:00pm. With the upcoming increase in temperatures, please water wisely to insure the most efficient use of outdoor watering. We appreciate your assistance in water conservation. Agate Water Company
close-image